0
We're unable to sign you in at this time. Please try again in a few minutes.
Retry
We were able to sign you in, but your subscription(s) could not be found. Please try again in a few minutes.
Retry
There may be a problem with your account. Please contact the AMA Service Center to resolve this issue.
Contact the AMA Service Center:
Telephone: 1 (800) 262-2350 or 1 (312) 670-7827  *   Email: subscriptions@jamanetwork.com
Error Message ......
Poster Session | ONLINE FIRST

Detection of Colon Cancer Metastases With Fluorescence Laparoscopy in Orthotopic Nude Mouse Models FREE

Rhiana S. Menen, MD; Sharmeela Kaushal, PhD; Cynthia S. Snyder, MD; Mark A. Talamini, MD; Robert M. Hoffman, PhD; Michael Bouvet, MD
[+] Author Affiliations

Author Affiliations: Department of Surgery, University of California, San Diego (Drs Menen, Kaushal, Snyder, Talamini, Hoffman, and Bouvet), Department of Surgery, University of California, San Francisco (Dr Menen), and AntiCancer Inc, San Diego, California (Drs Menen and Hoffman).


Arch Surg. 2012;147(9):876-880. doi:10.1001/archsurg.2012.704.
Text Size: A A A
Published online

Objective To improve detection of colon cancer metastases using fluorescence laparoscopy (FL).

Design An orthotopic mouse model of human colon cancer was established by intracecal injection of HCT-116 human colon cancer cells expressing green fluorescent protein into 12 mice. One group modeled early disease and the second modeled late metastatic disease. For the early-disease model, 2 weeks after implantation, 6 mice underwent 2 modalities of laparoscopy: bright field laparoscopy (BL) and FL. The number of metastases identified within each of the 4 abdominal quadrants was recorded with both laparoscopy modalities. This process was repeated in the late-metastatic disease group 4 weeks after implantation. All animals were then humanely sacrificed and imaged using open fluorescence laparoscopy (OL) as a positive control to identify metastases.

Setting Basic science laboratory.

Participants Twelve female, 6-week-old nude mice.

Interventions Detection of tumor foci by FL compared with BL.

Main Outcome Measures Number of tumors identified in each quadrant.

Results Fluorescence laparoscopy enabled superior visualization of colon cancer metastases compared with BL in the early (P = .03) and late (P = .002) models of colon cancer. Compared with OL, BL was significantly inferior in the early (P = .04) and late (P < .001) groups. Fluorescence laparoscopy was not significantly different from OL in the early (P = .85) or late (P = .46) group. Thus, FL allowed identification of micrometastases that could not be distinguished from surrounding tissue using BL.

Conclusions The use of FL enables identification of metastases that could not be visualized using standard laparoscopy. This report illustrates the important clinical potential for FL in the surgical treatment of cancer.

Figures in this Article

Diagnostic and staging laparoscopy is a minimally invasive surgical procedure that allows for more precise visual examination of intra-abdominal organs. Patients with liver metastases from colorectal cancer may be candidates for curative resection provided no other extrahepatic disease exists and all hepatic lesions are resectable. Laparoscopy in these patients can enable more accuracy than noninvasive imaging for identification of hepatic lesions, including size, number, and location.1 The combination of staging laparoscopy and laparoscopic ultrasonography has better sensitivity than noninvasive imaging studies in the detection of nodal metastases (94% laparoscopic ultrasonography vs 18% preoperative noninvasive imaging).2 Indeed, the use of both laparoscopic modalities detects unresectable disease in 25% to 42% of patients in whom preoperative radiologic testing demonstrated potentially curable disease.36 Thus, diagnostic laparoscopy can visualize peritoneal and liver metastases in colon cancer that would otherwise go undetected by preoperative imaging. Patients with cancer deemed unresectable by diagnostic laparoscopy are spared the pain, morbidity and expense of surgery, as well as delay to start of chemotherapy.

The superior ability of fluorescence laparoscopy (FL) to visualize pancreatic tumors not seen with standard laparoscopy has been previously reported.79 The aim of the present study was to improve detection of colon cancer with the use of FL in an orthotopic nude mouse model of human colon cancer, stably expressing green fluorescent protein (GFP).

CELL CULTURE

Human HCT-116 colon cancer cells were stably transduced to express GFP, as previously described.10 These cells were maintained in Dulbecco modified Eagle medium (Gibco-BRL) supplemented with 10% fetal bovine serum (Hyclone), penicillin-streptomycin (Gibco-BRL), sodium pyruvate (Gibco-BRL), sodium bicarbonate (Cellgro), L-glutamine (Gibco-BRL), and minimal essential medium supplemented with nonessential amino acids (Gibco-BRL). Cells were incubated at 37°C with a 5% carbon dioxide air mixture.

ANIMAL CARE

Female, athymic, nu/nu nude mice were maintained in a barrier facility in high-efficiency particulate air-filtered racks. The animals were fed an autoclaved, laboratory rodent diet (Teckland LM-485; Western Research Products). All surgical procedures were performed with the mice under anesthesia with intramuscular injection of a 100-μL mixture of ketamine, 100 mg/kg, and xylazine, 10 mg/kg. For each procedure, 20 μL buprenorphine, 1 mg/kg, was administered for pain control.

Euthanasia was achieved by 100% carbon dioxide inhalation, followed by cervical dislocation. All animal studies were approved by the University of California, San Diego, Institutional Animal Care and Use Committee and conducted in accordance with the principles and procedures outlined in the National Institutes of Health Guide for the Care and Use of Animals.

COLON CANCER ORTHOTOPIC NUDE MOUSE MODEL

The HCT-116 GFP cells were harvested by trypsinization and washed 3 times with serum-free medium. Viability was verified to be greater than 95% using the Vi-Cell XR automated cell viability analyzer (Beckman Coulter). The cells were resuspended at 106 cells per 10 μL of serum-free medium and placed on ice before orthotopic intracecal injection was performed in 12 female, 6-week-old nude mice.

LAPAROSCOPY

The methods for achieving maximal fluorescence signals and differentiation from background and surrounding tissues, by modifying a standard laparoscopic system, have been previously described (Stryker).7,8,11 In the present study, a Stryker L9000 light-emitting diode (LED) light source allowed adjustment of blue, green, and red LEDs using L9000 calibration software to achieve optimal background and GFP illumination (Figure 1). An emission filter (GG495 Schott glass) was placed between the scope and Stryker Camera 1288 (Figure 2). Mice were divided into 2 groups: early and late cancer. A small incision was made in the abdominal midline through which a 3-mm-diameter 0° Karl-Storz laparoscope (Karl-Storz GmbH & Co) was introduced and connected to standard insufflation tubing on the laparoscopic tower. A purse-string suture was placed around this incision to prevent its widening and to maintain proper insufflation at 1 mm Hg insufflation pressure. First, laparoscopic inspection was performed using standard bright light, and tumor foci were identified and recorded by quadrant. Second, laparoscopy was performed and tumor burden was recorded in the same manner using fluorescence light and filters. Animals were then euthanized, and open fluorescence laparoscopy (OL) was performed by quadrant as the positive standard for tumor detection. Tumor samples were reserved and processed for histologic analysis.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 1. Photograph of a representative mouse undergoing fluorescence laparoscopy. The Stryker L9000 light-emitting diode (LED) light source allowed adjustment of blue, green, and red LEDs by L9000 calibration software to achieve optimal background and green fluorescent protein illumination.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 2. Schematic illustration of the integrated bright-field and fluorescence laparoscopic setup adapted to a standard Stryker laparoscopic tower. Through a 495 emission filter, the light-emitting diode (LED) allows visualization of fluorescent tumors.11 The xenon light source is used for bright-light laparoscopy.

TISSUE HISTOLOGIC ANALYSIS

At necropsy, fresh tissues were fixed in Bouin solution and embedded in paraffin before sectioning and staining with hematoxylin-eosin for standard light microscopy. Hematoxylin-eosin–stained permanent sections were examined using an Olympus BX41 microscope equipped with a Micropublisher 3.3 RTV camera (QImaging). All images were acquired using QCapture software (QImaging) and adjusted for brightness and color balance. The slides were reviewed by a pathologist (C.S.S.) to confirm the identity of the fluorescent lesions.

DATA PROCESSING

Images obtained during laparoscopy were not processed in any way. Representative frames were selected and presented in this report. Histologic images were processed for brightness and contrast using Photoshop Element 4 (Adobe Systems Inc).

Two weeks after cecal implantation of HCT-116 for human colon cancer cells, 6 mice were designated for the early colon cancer model. Laparoscopic examination of all 4 quadrants was performed initially under bright-field laparoscopy (BL) and then under FL. The number of tumor foci for each quadrant was recorded for each modality. Next, mice were humanely sacrificed and OL was performed as the positive control. This process was repeated in 6 mice 4 weeks after cecal implant and designated the late model of colon cancer. Figure 3 shows representative images of BL and FL of early colon cancer. The tumor edges were clearly distinguished compared with background tissue under FL but not BL. For correlation of laparoscopic findings with tissue histologic findings, fluorescent lesions were identified postmortem using OL. The lesions were inked and processed for histologic analyses. Figure 4 shows the histologic confirmation of colon cancer in an abdominal wall tumor deposit, identified using FL.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 3. Comparison of bright-field laparoscopy (BL) and fluorescence laparoscopy (FL). A, BL of the left upper quadrant in a mouse with early cancer. Arrow identifies tumor. B, FL of same mouse. C, BL of the left lower quadrant in a mouse with late cancer. D, FL of the same mouse. Arrows indicate tumor foci (black in BL and white in FL). Note the difficulty distinguishing tumor foci from surrounding tissue using BL compared with FL.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 4. Histologic appearance of tumor deposit identified using fluorescence laparoscopy. This hematoxylin-eosin–stained tissue section shows a small tumor (Tu) implant growing on the peritoneal surface of the abdominal wall. m indicates muscle; s, skin.

In the early cancer group, when totaling all 6 mice, no tumors were detected in the right upper quadrant or left upper quadrant using any modality. In the right lower quadrant, BL was unable to detect any tumor foci, although FL detected 18 tumors. Twenty-two individual tumor foci were detected by OL. In the left lower quadrant, BL detected 6 tumor foci, whereas FL detected 26 tumor foci and OL detected 27 tumor foci. Overall, in the early cancer group, FL detected 44 metastatic foci, or 90% of the total metastases detected by OL, compared with only 6, or 12% of the total metastases detected by OL, in the BL group (P = .03) (Figure 5). In the early cancer group, the positive-control OL detected 46 metastatic foci (P = .04 compared with BL). No significant difference was found between FL and OL (P = .85).

Place holder to copy figure label and caption
Graphic Jump Location

Figure 5. Early colon tumor detection by bright-field laparoscopy (BL) vs fluorescence laparoscopy (FL). Open fluorescence laparoscopy (OL) was used as the positive control. Results represent the total number of metastases identified in all 6 animals and all 4 quadrants examined. Using OL, 46 metastases were identified in the early tumor group of mice, depicted here as 100%. Using BL, only 6 metastases, or 12%, were identified compared with OL (P = .04); compared with 44 metastases, or 90%, using FL (P = .03). Compared with OL, FL was not significantly different (P = .85).

In the late cancer group, in all 6 mice, extensive tumor burden was encountered in all quadrants (Figure 3). In the right upper quadrant, BL detected 41 tumor foci, whereas FL detected 122 tumor foci and OL detected 137 tumor foci. In the left upper quadrant, BL detected 62 tumor foci, whereas FL detected 130 tumor foci and OL detected 162 tumor foci. In the right lower quadrant, BL detected 60 tumor foci, whereas FL detected 141 tumor foci and OL detected 173 tumor foci. In the left lower quadrant, BL detected 44 total tumor foci, whereas FL detected 109 tumor foci and OL detected 115 tumor foci. Overall, in the late group, FL detected 502 metastatic foci, or 86% of the total metastases detected by OL, compared with 207, or 35% of the total metastases detected by OL, in the BL late group (P = .002). In the late group, the positive-control OL detected 587 metastatic foci (P < .001 compared with BL). No significant difference was found between FL and OL (P = .46) (Figure 6).

Place holder to copy figure label and caption
Graphic Jump Location

Figure 6. Late colon cancer detection by bright-field laparoscopy (BL) vs fluorescence laparoscopy (FL). Open fluorescence laparoscopy (OL) was used as the positive control in this setting. Results represent the total number of metastatic foci identified in all 6 animals and all 4 quadrants examined in each animal. Using OL, 587 metastatic foci were identified in the late tumor group of mice, depicted here as 100%. Using BL, only 207 metastatic foci, or 35%, were identified compared with OL (P < .001) and compared with 502 metastatic foci, or 86%, using FL (P = .002). FL compared with OL was not significantly different (P = .46).

Although GFP-labeled cancer cells used in this study to implant in the mice, provide a convenient tool, in situ labeling of tumors must be accomplished before translation to human patients. In their review of the current techniques for fluorescence-guided surgery, Bouvet and Hoffman12 compared several approaches for in vivo tumor labeling. In one set of studies, a monoclonal antibody, directed against either cancer antigen 19-9 (CA19-9) or carcinoembryonic antigen (CEA), was conjugated to a green fluorophore and delivered intravenously into nude mice with orthotopic human pancreatic or colon tumors.13,14 Once the fluorescent antibodies adhered to the CEA or CA19-9 antigens of CEA- or CA19-9–expressing cancer cells, respectively, the tumors become fluorescent. Tumors that were invisible with standard bright field imaging demonstrated clear fluorescence and under fluorescence guidance resulted in more complete resection. Kishimoto et al15,16 reported the use of a telomerase-dependent adenovirus with the GFP gene to label tumors.

The concept of FL is new and expanding. Several groups are exploring near-infrared (NIR) FL to improve surgical navigation. For instance, Ankersmit et al17 described the technique of sentinel lymph node mapping using NIR dyes visualized with a laparoscopic NIR fluorescence imaging system for colorectal cancer. Similarly, Cahill and Mortensen18 used NIR imaging, along with more conventional laparoscopic imaging, to better distinguish tissue architecture and lymphatic and vascular-channel anatomy.

Wavelengths in the NIR range (700-900 nm) have the advantage of penetrating deeply into living tissue compared with visible light that is used in sentinel lymph node mapping. However, NIR fluoroscopy cannot be seen with the naked eye and therefore requires a specialized laparoscope to visualize the fluorophore. In contrast, the fluorescence equipment used in the present study uses an LED L9000 light source that is already standard in most operating rooms and therefore needs minimal adaptation for translation to clinical practice.

In the current study, GFP-labeled cancer cells were implanted into the cecum of 12 mice to establish early and late models of colon cancer. Fluorescence laparoscopy enabled superior visualization of colon cancer metastatic foci not visualized with standard BL in the early and late cancer models when compared with the positive-control OL. Open fluorescence laparoscopy may appear more accurate than FL, although not significantly so, simply because of limitations in delineating quadrant location. In addition, placement of a single port at the intersection of the 4 quadrants made identification of peritoneal metastases adjacent to the scope impossible. For translation into human patients, these limitations can be easily overcome by placement of multiple port sites, as is traditionally done, thus allowing for complete inspection of the peritoneum and abdominal wall.

The FL technology described in the present report represents the way forward for cancer surgery and staging. Enhancing a surgeon's ability to identify primary and metastatic tumors and distinguish tumors from surrounding vital structures, makes FL an exciting and important development. Chimerization of antibodies for use in humans has precedent in monoclonal antibody drugs, such as rituximab, which is routinely used for patients with non-Hodgkin lymphoma and rheumatoid arthritis19; trastuzumab, which is used in breast cancer20; and cetuximab, which is used in colon cancer.21 Thus, fluorescent chimeric antibodies are promising for clinical application of FL. Alternatively, the bright fluorescence of GFP can be selectively delivered to tumors via a cancer cell–selective telomerase-dependent adenovirus.15,16 Such advances make the use of FL a real possibility for clinical applicability in the near future. The use of FL enables the identification of metastases that would otherwise be missed using standard laparoscopy. Fluorescence laparoscopy could then be used not only in staging laparoscopy but also to improve the localization of liver metastases for resection or radiofrequency ablative techniques.22

Correspondence: Michael Bouvet, MD, University of California, San Diego, Moores Cancer Center, 3855 Health Sciences Dr, Ste 0987, La Jolla, CA 92093-0987 (mbouvet@ucsd.edu).

Accepted for Publication: March 9, 2012.

Published Online: May 21, 2012. doi:10.1001 /archsurg.2012.704

Author Contributions:Study concept and design: Menen, Kaushal, Hoffman, and Bouvet. Acquisition of data: Menen, Kaushal, and Snyder. Analysis and interpretation of data: Menen, Kaushal, Snyder, Talamini, Hoffman, and Bouvet. Drafting of the manuscript: Menen. Critical revision of the manuscript for important intellectual content: Menen, Snyder, Hoffman, and Bouvet. Statistical analysis: Menen. Administrative, technical, and material support: Bouvet. Study supervision: Talamini, Bouvet, and Hoffman.

Financial Disclosure: None reported.

Funding/Support: This study was supported in part by grants CA142669 and CA132971 to Dr Bouvet and AntiCancer Inc and a Society of University Surgeons training grant to Dr Menen.

Previous Presentation: This study was presented as a poster presentation at the 83rd Annual Meeting of the Pacific Coast Surgical Association; February 18, 2012; Napa Valley, California; and is published after peer review and revision.

Guidelines for Diagnostic Laparoscopy.  Practice/Clinical Guidelines published on 11/2007 by the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES). http://www.sages.org/publication/id/12/. Accessed March 8, 2012
Goletti O, Celona G, Galatioto C,  et al.  Is laparoscopic sonography a reliable and sensitive procedure for staging colorectal cancer? a comparative study.  Surg Endosc. 1998;12(10):1236-1241
PubMed   |  Link to Article
Hayashi M, Komeda K, Inoue Y,  et al.  Simultaneous laparoscopic resection of colorectal cancer and synchronous metastatic liver tumor.  Int Surg. 2011;96(1):74-81
PubMed
Jarnagin WR, Conlon K, Bodniewicz J,  et al.  A clinical scoring system predicts the yield of diagnostic laparoscopy in patients with potentially resectable hepatic colorectal metastases.  Cancer. 2001;91(6):1121-1128
PubMed   |  Link to Article
Rahusen FD, Cuesta MA, Borgstein PJ,  et al.  Selection of patients for resection of colorectal metastases to the liver using diagnostic laparoscopy and laparoscopic ultrasonography.  Ann Surg. 1999;230(1):31-37
PubMed   |  Link to Article
Thaler K, Kanneganti S, Khajanchee Y, Wilson C, Swanstrom L, Hansen PD. The evolving role of staging laparoscopy in the treatment of colorectal hepatic metastasis.  Arch Surg. 2005;140(8):727-734
PubMed   |  Link to Article
Tran Cao HS, Kaushal S, Lee C,  et al.  Fluorescence laparoscopy imaging of pancreatic tumor progression in an orthotopic mouse model.  Surg Endosc. 2011;25(1):48-54
PubMed   |  Link to Article
Tran Cao HS, Kaushal S, Menen RS,  et al.  Submillimeter-resolution fluorescence laparoscopy of pancreatic cancer in a carcinomatosis mouse model visualizes metastases not seen with standard laparoscopy.  J Laparoendosc Adv Surg Tech A. 2011;21(6):485-489
PubMed   |  Link to Article
Cao HS, Kaushal S, Metildi CA,  et al.  Tumor-specific fluorescence antibody imaging enables accurate staging laparoscopy in an orthotopic model of pancreatic cancer [published online ahead of print].  Hepatogastroenterology. 2012;59(118):Link to Article
PubMed
Bouvet M, Tsuji K, Yang M, Jiang P, Moossa AR, Hoffman RM. In vivo color-coded imaging of the interaction of colon cancer cells and splenocytes in the formation of liver metastases.  Cancer Res. 2006;66(23):11293-11297
PubMed   |  Link to Article
Metildi CA, Kaushal S, Lee C,  et al.  An LED light source and novel fluorophore combinations improve fluorescence laparoscopic detection of metastatic pancreatic cancer in orthotopic mouse models.  J Am Coll SurgIn press
Bouvet M, Hoffman RM. Glowing tumors make for better detection and resection.  Sci Transl Med. 2011;3:110fs10
PubMed  |  Link to Article   |  Link to Article
Kaushal S, McElroy MK, Luiken GA,  et al.  Fluorophore-conjugated anti-CEA antibody for the intraoperative imaging of pancreatic and colorectal cancer.  J Gastrointest Surg. 2008;12(11):1938-1950
PubMed   |  Link to Article
McElroy M, Kaushal S, Luiken GA,  et al.  Imaging of primary and metastatic pancreatic cancer using a fluorophore-conjugated anti-CA19-9 antibody for surgical navigation.  World J Surg. 2008;32(6):1057-1066
PubMed   |  Link to Article
Kishimoto H, Aki R, Urata Y,  et al.  Tumor-selective, adenoviral-mediated GFP genetic labeling of human cancer in the live mouse reports future recurrence after resection.  Cell Cycle. 2011;10(16):2737-2741
PubMed   |  Link to Article
Kishimoto H, Zhao M, Hayashi K,  et al.  In vivo internal tumor illumination by telomerase-dependent adenoviral GFP for precise surgical navigation.  Proc Natl Acad Sci U S A. 2009;106(34):14514-14517
PubMed   |  Link to Article
Ankersmit M, van der Pas MH, van Dam DA, Meijerink WJ. Near infrared fluorescence lymphatic laparoscopy of the colon and mesocolon.  Colorectal Dis. 2011;13:(suppl 7)  70-73
PubMed   |  Link to Article
Cahill RA, Mortensen NJ. Intraoperative augmented reality for laparoscopic colorectal surgery by intraoperative near-infrared fluorescence imaging and optical coherence tomography.  Minerva Chir. 2010;65(4):451-462
PubMed
Buch MH, Smolen JS, Betteridge N,  et al; Rituximab Consensus Expert Committee.  Updated consensus statement on the use of rituximab in patients with rheumatoid arthritis.  Ann Rheum Dis. 2011;70(6):909-920
PubMed   |  Link to Article
Harries M, Smith I. The development and clinical use of trastuzumab (Herceptin).  Endocr Relat Cancer. 2002;9(2):75-85
PubMed   |  Link to Article
Jonker DJ, O’Callaghan CJ, Karapetis CS,  et al.  Cetuximab for the treatment of colorectal cancer.  N Engl J Med. 2007;357(20):2040-2048
PubMed   |  Link to Article
Siperstein AE, Berber E, Ballem N, Parikh RT. Survival after radiofrequency ablation of colorectal liver metastases: 10-year experience.  Ann Surg. 2007;246(4):559-567
PubMed   |  Link to Article

Figures

Place holder to copy figure label and caption
Graphic Jump Location

Figure 1. Photograph of a representative mouse undergoing fluorescence laparoscopy. The Stryker L9000 light-emitting diode (LED) light source allowed adjustment of blue, green, and red LEDs by L9000 calibration software to achieve optimal background and green fluorescent protein illumination.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 2. Schematic illustration of the integrated bright-field and fluorescence laparoscopic setup adapted to a standard Stryker laparoscopic tower. Through a 495 emission filter, the light-emitting diode (LED) allows visualization of fluorescent tumors.11 The xenon light source is used for bright-light laparoscopy.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 3. Comparison of bright-field laparoscopy (BL) and fluorescence laparoscopy (FL). A, BL of the left upper quadrant in a mouse with early cancer. Arrow identifies tumor. B, FL of same mouse. C, BL of the left lower quadrant in a mouse with late cancer. D, FL of the same mouse. Arrows indicate tumor foci (black in BL and white in FL). Note the difficulty distinguishing tumor foci from surrounding tissue using BL compared with FL.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 4. Histologic appearance of tumor deposit identified using fluorescence laparoscopy. This hematoxylin-eosin–stained tissue section shows a small tumor (Tu) implant growing on the peritoneal surface of the abdominal wall. m indicates muscle; s, skin.

Place holder to copy figure label and caption
Graphic Jump Location

Figure 5. Early colon tumor detection by bright-field laparoscopy (BL) vs fluorescence laparoscopy (FL). Open fluorescence laparoscopy (OL) was used as the positive control. Results represent the total number of metastases identified in all 6 animals and all 4 quadrants examined. Using OL, 46 metastases were identified in the early tumor group of mice, depicted here as 100%. Using BL, only 6 metastases, or 12%, were identified compared with OL (P = .04); compared with 44 metastases, or 90%, using FL (P = .03). Compared with OL, FL was not significantly different (P = .85).

Place holder to copy figure label and caption
Graphic Jump Location

Figure 6. Late colon cancer detection by bright-field laparoscopy (BL) vs fluorescence laparoscopy (FL). Open fluorescence laparoscopy (OL) was used as the positive control in this setting. Results represent the total number of metastatic foci identified in all 6 animals and all 4 quadrants examined in each animal. Using OL, 587 metastatic foci were identified in the late tumor group of mice, depicted here as 100%. Using BL, only 207 metastatic foci, or 35%, were identified compared with OL (P < .001) and compared with 502 metastatic foci, or 86%, using FL (P = .002). FL compared with OL was not significantly different (P = .46).

Tables

References

Guidelines for Diagnostic Laparoscopy.  Practice/Clinical Guidelines published on 11/2007 by the Society of American Gastrointestinal and Endoscopic Surgeons (SAGES). http://www.sages.org/publication/id/12/. Accessed March 8, 2012
Goletti O, Celona G, Galatioto C,  et al.  Is laparoscopic sonography a reliable and sensitive procedure for staging colorectal cancer? a comparative study.  Surg Endosc. 1998;12(10):1236-1241
PubMed   |  Link to Article
Hayashi M, Komeda K, Inoue Y,  et al.  Simultaneous laparoscopic resection of colorectal cancer and synchronous metastatic liver tumor.  Int Surg. 2011;96(1):74-81
PubMed
Jarnagin WR, Conlon K, Bodniewicz J,  et al.  A clinical scoring system predicts the yield of diagnostic laparoscopy in patients with potentially resectable hepatic colorectal metastases.  Cancer. 2001;91(6):1121-1128
PubMed   |  Link to Article
Rahusen FD, Cuesta MA, Borgstein PJ,  et al.  Selection of patients for resection of colorectal metastases to the liver using diagnostic laparoscopy and laparoscopic ultrasonography.  Ann Surg. 1999;230(1):31-37
PubMed   |  Link to Article
Thaler K, Kanneganti S, Khajanchee Y, Wilson C, Swanstrom L, Hansen PD. The evolving role of staging laparoscopy in the treatment of colorectal hepatic metastasis.  Arch Surg. 2005;140(8):727-734
PubMed   |  Link to Article
Tran Cao HS, Kaushal S, Lee C,  et al.  Fluorescence laparoscopy imaging of pancreatic tumor progression in an orthotopic mouse model.  Surg Endosc. 2011;25(1):48-54
PubMed   |  Link to Article
Tran Cao HS, Kaushal S, Menen RS,  et al.  Submillimeter-resolution fluorescence laparoscopy of pancreatic cancer in a carcinomatosis mouse model visualizes metastases not seen with standard laparoscopy.  J Laparoendosc Adv Surg Tech A. 2011;21(6):485-489
PubMed   |  Link to Article
Cao HS, Kaushal S, Metildi CA,  et al.  Tumor-specific fluorescence antibody imaging enables accurate staging laparoscopy in an orthotopic model of pancreatic cancer [published online ahead of print].  Hepatogastroenterology. 2012;59(118):Link to Article
PubMed
Bouvet M, Tsuji K, Yang M, Jiang P, Moossa AR, Hoffman RM. In vivo color-coded imaging of the interaction of colon cancer cells and splenocytes in the formation of liver metastases.  Cancer Res. 2006;66(23):11293-11297
PubMed   |  Link to Article
Metildi CA, Kaushal S, Lee C,  et al.  An LED light source and novel fluorophore combinations improve fluorescence laparoscopic detection of metastatic pancreatic cancer in orthotopic mouse models.  J Am Coll SurgIn press
Bouvet M, Hoffman RM. Glowing tumors make for better detection and resection.  Sci Transl Med. 2011;3:110fs10
PubMed  |  Link to Article   |  Link to Article
Kaushal S, McElroy MK, Luiken GA,  et al.  Fluorophore-conjugated anti-CEA antibody for the intraoperative imaging of pancreatic and colorectal cancer.  J Gastrointest Surg. 2008;12(11):1938-1950
PubMed   |  Link to Article
McElroy M, Kaushal S, Luiken GA,  et al.  Imaging of primary and metastatic pancreatic cancer using a fluorophore-conjugated anti-CA19-9 antibody for surgical navigation.  World J Surg. 2008;32(6):1057-1066
PubMed   |  Link to Article
Kishimoto H, Aki R, Urata Y,  et al.  Tumor-selective, adenoviral-mediated GFP genetic labeling of human cancer in the live mouse reports future recurrence after resection.  Cell Cycle. 2011;10(16):2737-2741
PubMed   |  Link to Article
Kishimoto H, Zhao M, Hayashi K,  et al.  In vivo internal tumor illumination by telomerase-dependent adenoviral GFP for precise surgical navigation.  Proc Natl Acad Sci U S A. 2009;106(34):14514-14517
PubMed   |  Link to Article
Ankersmit M, van der Pas MH, van Dam DA, Meijerink WJ. Near infrared fluorescence lymphatic laparoscopy of the colon and mesocolon.  Colorectal Dis. 2011;13:(suppl 7)  70-73
PubMed   |  Link to Article
Cahill RA, Mortensen NJ. Intraoperative augmented reality for laparoscopic colorectal surgery by intraoperative near-infrared fluorescence imaging and optical coherence tomography.  Minerva Chir. 2010;65(4):451-462
PubMed
Buch MH, Smolen JS, Betteridge N,  et al; Rituximab Consensus Expert Committee.  Updated consensus statement on the use of rituximab in patients with rheumatoid arthritis.  Ann Rheum Dis. 2011;70(6):909-920
PubMed   |  Link to Article
Harries M, Smith I. The development and clinical use of trastuzumab (Herceptin).  Endocr Relat Cancer. 2002;9(2):75-85
PubMed   |  Link to Article
Jonker DJ, O’Callaghan CJ, Karapetis CS,  et al.  Cetuximab for the treatment of colorectal cancer.  N Engl J Med. 2007;357(20):2040-2048
PubMed   |  Link to Article
Siperstein AE, Berber E, Ballem N, Parikh RT. Survival after radiofrequency ablation of colorectal liver metastases: 10-year experience.  Ann Surg. 2007;246(4):559-567
PubMed   |  Link to Article

Correspondence

CME
Also Meets CME requirements for:
Browse CME for all U.S. States
Accreditation Information
The American Medical Association is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians. The AMA designates this journal-based CME activity for a maximum of 1 AMA PRA Category 1 CreditTM per course. Physicians should claim only the credit commensurate with the extent of their participation in the activity. Physicians who complete the CME course and score at least 80% correct on the quiz are eligible for AMA PRA Category 1 CreditTM.
Note: You must get at least of the answers correct to pass this quiz.
Please click the checkbox indicating that you have read the full article in order to submit your answers.
Your answers have been saved for later.
You have not filled in all the answers to complete this quiz
The following questions were not answered:
Sorry, you have unsuccessfully completed this CME quiz with a score of
The following questions were not answered correctly:
Commitment to Change (optional):
Indicate what change(s) you will implement in your practice, if any, based on this CME course.
Your quiz results:
The filled radio buttons indicate your responses. The preferred responses are highlighted
For CME Course: A Proposed Model for Initial Assessment and Management of Acute Heart Failure Syndromes
Indicate what changes(s) you will implement in your practice, if any, based on this CME course.

Multimedia

Some tools below are only available to our subscribers or users with an online account.

1,124 Views
2 Citations
×

Related Content

Customize your page view by dragging & repositioning the boxes below.

Jobs