RT Journal A1 HAMELBERG W, SIDDALL J, CLAASSEN L T1 PErforation of dura by a plastic catheter during continuous caudal anesthesia JF A.M.A. Archives of Surgery JO A.M.A. Archives of Surgery YR 1959 FD February 1 VO 78 IS 2 SP 357 OP 358 DO 10.1001/archsurg.1959.04320020179027 UL http://dx.doi.org/10.1001/archsurg.1959.04320020179027 AB Occasional perforation of the dura is a well-recognized possibility following the insertion of a needle into the caudal canal. Perforation of the dura by a plastic catheter passed through a needle in the caudal canal is rare. A review of the literature discloses several reports of dural perforation using malleable needles, but none following the use of a plastic catheter. The following is a case report of such an occurrence.Report of CaseĀ  The patient, a 60-year-old man, was admitted for elective repair of bilateral inguinal hernia. The past history was relevant in that 43 years prior to admission the patient had had rheumatic fever, resulting in rheumatic heart disease. At the time of surgery, he had mitral stenosis and at rial fibrillation without evidence of cardiac failure. An electrocardiogram showed left ventricular hypertrophy, auricular fibrillation, premature ventricular extrasystoles, and an old posterior myocardial infarct. All other physical and laboratory